HYGIENIC BASIS FOR MONITORING OF PMD
DOI:
https://doi.org/10.31618/asj.2707-9864.2020.1.44.62Keywords:
HYGIENICAbstract
A rational criterion for the hygienic relevance of the surface area of dust settling in the lungs is formulated in the article.
The differential parameters of airborne dust are determined by measuring the mass concentration of particular matter PM10 and PM2.5. A unified model of the behavior of dust in the lungs has been developed. It describes the deposition of particles on the walls of the airways when cleaning the inhaled air and the subsequent removal of settled dust from the lungs.
The adequacy of the model was verified by the compliance with the results of in vivo testing. The phenomenon of dust deposition in the lungs is described. It is typical for periodic dust exposure in the workplace. Dust exposure is acceptable if the surface area of the deposited dust does not exceed the area of the internal surface of the airways. With this approach, the concentration of dust in inhaled air is recomputed into the surface area of dust particles deposited in the lungs. As the initial data, the results of routine measurements of the mass concentration of particulate matter PM10 and PM2.5 are used. Permissible concentration for PM10 close to the WHO Recommendations and adopted in industrialized countries. Permissible concentration for PM2.5 should be a lot stiffer than currently accepted.
In reality, only the pair PM10 and РМ2,5 gives a quantitative characteristic of the danger of dust exposure. It determines the entering to the area of permissible dust exposure.
References
Krewski D et al. Extended follow-up and spatial analysis of the American Cancer Society linking particulate air pollution and mortality. Boston, MA, Health Effects Institute, 2009 (HEI Research Report 140).
Pope CA III et al. Lung cancer, cardiopulmonary mortality, and long-term exposure to fine particulate air pollution. Journal of the American Medical Association, 287(9): 2002, P. 1132–1141.
Stanek LW et al. Attributing health effects to apportioned components and sources of particulate matter: an evaluation of collective results. Atmospheric Environment, 45: 2011, P. 5655– 5663.
World Health Organization 2006, Air Quality Guidelines, Global Update WHO Regional Office for Europe, 2005.
Brown, D.M., Wilson, M.R., MacNee, W., Stone, V. and Donaldson, K. Size-dependent proinflammatory effects of ultrafine polystyrene particles: A role for surface area and oxidative stress in the enhanced activity of ultrafines. Toxicology and Applied Pharmacology, 175 (3), 2001, pp.191-199
Fedorovich G.V. A role of inertial mechanism for clearance of aerosol particle in the lung. Russian Pulmonology. 2013;(2):114-118. (In Russ.) Available on: https://doi.org/10.18093/0869-0189-2013-0-2-114-118
Fedorovich G.V. Model of mucociliary clearance of the lung. Russian Pulmonology. 2016;26(2):222-230. (In Russ.)
Available on: https://doi.org/10.18093/0869-0189-2016-26-2-222-230
Weibel E. R., Morphometry of the Human Lung. New York: Academic, 1963 – 196 р.
Fedorovitch G.V., Aerosol Particles in Lungs. Theoretical Modeling of Deposition and Mucociliary Clearance. In Rhinosinusitis (Ed. Gendeh B.S. and Turkalj M.) IntechOpen, London, UK, 2019, P.166.
Comer J.K, Kleinstreuer C,, Zhang Z. Flow structures and particle deposition patterns in doublebifurcation airway models. 1. Air flow fields. J Fluid Mech435: 25–54, 2001.
Sturm R., Aerosol Bolus Inhalation as Technique for the Diagnosis of Various Lung Diseases – a Theoretical Approach // Computational and Mathematical Biology 2014, Issue 3 (2)
Kolmogorov A.N. On the log-normal law of particle size distribution during crushing. Dokl. Akad. Nauk SSSR 31 (1941), 99-101
Halmos P. R., Random alms. Ann. Math. Statist. 15, 1944, Р.182-189.
Epstein B., The mathematical description of certain breakage mechanisms leading to the logarithmico-normal distribution. J. Franklin Inst. 244, 1947, Р.471- 477.
M.Hori, M.Uchida, Application of theory of Markov processes to comminution., Kodai Math. Sem. Rep. 19 (1967), 174-188
Junge C. Comments on "concentration and size distribution measurements of atmospheric aerosols and a test of the theory of self-preserving size distributions"// J. Atmosph. Sci. 1969, Vol. 26, №3
Clark W.E., Whitby K.T., Condensation and size distribution measurements of atmospheric aerosols and a test of the theory of self-preserving size distribution // Jorn. Atmosph. Sci. 1967. Vol. 24, № 6.
Downloads
Published
Issue
Section
License
This work is licensed under a Creative Commons Attribution-NoDerivatives 4.0 International License.
CC BY-ND
A work licensed in this way allows the following:
1. The freedom to use and perform the work: The licensee must be allowed to make any use, private or public, of the work.
2. The freedom to study the work and apply the information: The licensee must be allowed to examine the work and to use the knowledge gained from the work in any way. The license may not, for example, restrict "reverse engineering."
2. The freedom to redistribute copies: Copies may be sold, swapped or given away for free, in the same form as the original.